Showing results: 46 - 60 of 158 items found.
-
72-1020 -
Tenma
This unit measures AC/DC voltage and current, resistance, capacitance, frequency, and temperature. It also provides diode and audible continuity test, as well as 4~20mA loop testing.
-
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
CYHCT-C2TV -
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used for measurement of DCcurrent etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
5658 -
Abaco Systems Inc
ECM P/N 5658 provides eight channels of 16 bit current measurement in the 0 to 25 milli-amp range. Each channel allows independent common mode voltages from -100 volts to +100 volts. Current detection is accomplished with a precision 100 ohm current sense resistor, creating a voltage drop of 2V in the current loop at 20 milli-amps.
-
Megger Group Ltd.
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
MPI-502 -
Sonel S.A.
Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling
-
PowerCheck 1557 -
Seaward Electronic Ltd
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Non-Linear Systems
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
NTN -
FuG Elektronik GmbH
High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units
-
LEO 3 -
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
Highland Technology, Inc.
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
1825 LP -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
AMETEK Drexelbrook
The IntelliPoint Loop Powered Two Wire provides a capacitance probe level switch with current output and “On-Board” self-diagnostics to ensure reliability and level sensing elements for a wide variety of temperatures, pressures, and materials.